Installation of electric underfloor heating does not differ from the version of the water, so we only briefly review the necessary steps.
First you need to decide where the thermostat setting and knock a hole in the wall to the mounting box. In most cases this is the usual case in which the installed switches and sockets. The height of the thermostat 50-100 cm
Once you are done, to the installation site from the junction box is necessary to bring the phase and ground zero. Now take the hands of hammer and chisel and break through the floor to the side groove in which to place the two plastic tubes. In one of them will take the power wire heating cable, so its length is equal to the distance from the floor up to the location of the thermostat. The other wiring necessary for the floor sensor, so its length should be approximately 1 meter higher, since the tube will still be packed and on the floor. For example, if during the operation of sensor fails, then unscrewing the thermostat floor sensor can be easily pulled through the box.
Once the wiring is done, you can proceed directly to sex. Here everything is exactly the same as in the water version: align the surface of the perimeter wall damping glue tape and insulation should be laid. Of course, if the bottom is heated room, heating cable may be mounted directly on the draft floor, but again, in most cases you will heat the ceiling of the neighbors. Therefore, heat-insulating layer with a thickness of at least two inches will be most welcome.